AS-Interface EMERGENCY STOP button VAA-2E1A-PM-S

VAA-2E1A-PM-S
  • 2-channel, compelled connected
  • Overload-protected in accordance with IEC 60947-5-5
  • Integrated illumination in the actuator
  • TÜV-approval for system components is available
  • Biased actuator for self-monitoring
  • EMERGENCY STOP unlocking by turning or pulling

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Last ned komplett datablad som PDF:


Datablad utdrag: Tekniske data for  VAA-2E1A-PM-S

Produktbeskrivelse
AS-Interface EMERGENCY STOP button
General specifications
Node typeSafety-Slave
AS-Interface specificationV2.1
Required master specification≥ V2.0
UL File NumberE198304
Functional safety related parameters
MTTFd200 a
B10d1 E+5
Electrical specifications
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Rated operating current≤ 40 mA
Protection classIII
Insulation resistancemin. 100 MΩ
Input
Number/Type2 NC
Safety function by positive opening
in accordance with IEC/EN 60947-5-1
Reset by pulling
Supplyfrom AS-Interface
Output
Number/TypeLED red
Supplyfrom AS-Interface
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 62026-2:2013
Standard conformity
Electromagnetic compatibilityEN 62026-2:2013
Degree of protectionEN 60529:2000
Electrical safetyEN 60947-5-5:1997+A1:2005
AS-InterfaceEN 62026-2:2013
Functional safetyEN 62061:2005
EN 61508 Parts 1-7:2010
NFPA 79:2007
EN 60204-1:2006
Programming instructions
ProfileS-7.B.E.
IO code7
ID codeB
ID1 codeF
ID2 codeE
Data bits (function via AS-Interface) input output
D0 dyn. safety code 1 OUT 1
D1 dyn. safety code 1 -
D2 dyn. safety code 2 -
D3 dyn. safety code 2 -
Parameter bits (programmable via AS-i)function
P0not used
P1not used
P2not used
P3not used
Ambient conditions
Ambient temperature-25 ... 55 °C (-13 ... 131 °F) (no freezing)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Relative humidity40 ... 85 % , noncondensing
Mechanical specifications
Operating forcePush: 32 N
Pull: 21 N
Turn: 0.27 Nm
Minimum for positive opening operation: 60 Nm
Operating distancefor positive opening operation: min. 4 mm
maximal: 4.5 mm
Degree of protectionIP65
ConnectionCrimp terminal sockets (JST)
1.5 m Connecting cable with crimp on 2 flexible leads supplied with delivery
InstallationInstallation in 22 mm hole
Mass105 g
Life span> 250,000 switching operations

Classifications

SystemClasscode
ECLASS 13.027371244
ECLASS 12.027371244
ECLASS 11.027371244
ECLASS 10.0.127371244
ECLASS 9.027371244
ECLASS 8.027371244
ECLASS 5.127371228
ETIM 9.0EC002034
ETIM 8.0EC002034
ETIM 7.0EC002034
ETIM 6.0EC002034
ETIM 5.0EC002034
UNSPSC 12.139121533

Details: VAA-2E1A-PM-S

Function

This AS-Interface emergency shutoff button is a two-channel, positively driven contact, allowing the operation of personnel protection systems when used according to specification along with an AS-Interface safety monitor. It occupies one complete address in the AS-Interface strand.

When the safety monitor is properly configured, up to  EN 954-1 Category 4 and IEC 61508 SIL 3 can be achieved.

For mounting, this AS-Interface emergency shutoff button can be screwed into the front plate of the machine or the switch panel. The button can be illuminated in red.

A designation plate and suitable connection cable are included in the scope of delivery.

Product Documentation: VAA-2E1A-PM-S

Velg språk:
Brief InstructionsSpråkFiltypeFilstørrelse
Instruction leaflet / BeipackzettelALLPDF330 KB

Design / Simulation: VAA-2E1A-PM-S

Velg språk:
CADSpråkFiltypeFilstørrelse
CAD 3-D / CAD 3-DALLSTP3618 KB

Approvals: VAA-2E1A-PM-S

Velg språk:
CertificatesSertifikatnummerSpråkFiltypeFilstørrelse
CA ULE198304ALLLINK---
US CA ULE198304ALLPDF233 KB
Worldwide AS-International Association AS-Interface75301ALLPDF621 KB

Software: VAA-2E1A-PM-S

Velg språk:
Software ToolsFrigivelsesinfoFiltypeFilstørrelse
SISTEMA SLB Library AS-Interface Safety / SISTEMA SLB Library AS-Interface SafetyZIP622 KB
Free Download: White Paper on TCP-Based Communication Protocols (PDF)

Dette gratis PDF-dokumentet sammenligner de forskjellige TCP-baserte kommunikasjonsprotokollene (AMQP, OPC UA, MQTT, REST API) som har funnet veien opp og regnes som muliggjørerne for IIoT og Industry 4.0. Last ned gratis nå!

AS-Interface Product Range

Get to know our full range of AS-Interface products.