Teknisk support Industrielle sensorer
Kundeservice, eksplosjonsbeskyttelse

Temperature Multi-Input Junction Box, Stainless Steel F.TI0.S12.*08.F.0.***.***.**00

F.TI0.S12.*08.F.0.***.***.**00
  • 8 channel universal temperature interface
  • Stainless steel, electropolished, IP66
  • Configurable cable entries for bus lines and field signal lines
  • International approvals
  • For FOUNDATION Fieldbus H1
  • Installation in Zone 1 and Zone 2

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Datablad utdrag: Tekniske data for  F.TI0.S12.*08.F.0.***.***.**00

General specifications
Design / MountingOutside installation
Installed componentsTemperature Multi-Input Device RD0-TI-Ex8.FF.ST
For technical data on installed electronic component see data sheet.
Conformity
Degree of protectionEN 60529
Impact resistanceEN 60079-0
Ambient conditions
Ambient temperature-30 ... 55 °C (-22 ... 131 °F) , (extended temperature range available on request)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Relative humidity< 75 % (annual mean)
< 95 % (30 d/year), no moisture condensation
Impact resistance7J
Mechanical specifications
Enclosure coverdetachable hinged door with captive retaining screws
Degree of protectionIP66
Cable entrycable gland and stopping plug options see separate table
Material
Housingstainless steel 1.4404 / AISI 316L
Surfaceelectropolished
SealNeoprene, fire-resistant, one piece
Material thicknessenclosure body, enclosure cover, mounting plate: 1.5 mm
gland plate: 3.0 mm
Dimensions(W x H x D)
300 x 200 x 120 mm (1 x RD0-TI-Ex8.FF.ST)
Mountingthru-holes Ø10 mm
Groundinggrounding bolt M10 , brass
Data for application in connection with hazardous areas
EU-Type Examination CertificatePTB 07 ATEX 1061 X (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
MarkingEx-Hexagon II 2(1)G Ex ia [ia Ga] IIC T4 Gb
Ex-Hexagon II 2(1)D Ex tb [ia Da] IIIC T135°C Db
CertificatePTB 17 ATEX 1011 X (assembled Junction Box) , for additional certificates see www.pepperl-fuchs.com
MarkingEx-Hexagon II 3G Ex ic IIC T4 Gc
Ex-Hexagon II 3G Ex nA IIC T4 Gc
Ex-Hexagon II 3D Ex tc IIIC T135°C Dc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-31:2014
International approvals
IECEx approvalIECEx PTB 07.0036 X , Zone 1 , suitable Junction Box on request
IECEx PTB 09.0016 X , Zone 2 , suitable Junction Box on request
INMETROTÜV 13.1143
General information
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027242610
ECLASS 12.027242610
ECLASS 11.027242610
ECLASS 10.0.127242610
ECLASS 9.027242610
ECLASS 8.027242610
ECLASS 5.127242610
ETIM 9.0EC001601
ETIM 8.0EC001601
ETIM 7.0EC001601
ETIM 6.0EC001601
ETIM 5.0EC001604
UNSPSC 12.139121008

Details: F.TI0.S12.*08.F.0.***.***.**00

This fieldbus junction box holds a temperature multi-input device for transferring signals from resistance temperature measuring sensors and thermocouples, as well as resistance and millivolt signals via FOUNDATION Fieldbus H1. The fieldbus junction box with 8 inputs can be installed in Zone 1 with sensors located in Zone 0.

Electropolished stainless steel 316L provides high corrosion and impact resistance at a very wide temperature range.

Bus and field signal line entries can be chosen individually from a range of cable glands and stopping plugs. A breather is included by default. Tag plate and grounding bar are available as options.

This junction box is available pre-wired, with all accessories, for fast ordering, delivery, site installation, and commissioning.

Datasheet: F.TI0.S12.*08.F.0.***.***.**00

DatasheetFiltypeFilstørrelse
Datasheet F.TI0.S12.*08.F.0.***.***.**00PDF537 KB
Datenblatt F.TI0.S12.*08.F.0.***.***.**00PDF537 KB

Documents: F.TI0.S12.*08.F.0.***.***.**00

ManualsFiltypeFilstørrelse
ManualPDF766 KB
Instruction manuals
ИнструкцииPDF155 KB
ИнструкцииPDF156 KB
Návod k poużitíPDF151 KB
Návod k poużitíPDF152 KB
Instruktions manualPDF151 KB
Instruktions manualPDF149 KB
Instruction manualPDF140 KB
Instruction manualPDF139 KB
KasutusjuhendPDF144 KB
KasutusjuhendPDF146 KB
KäyttöohjePDF144 KB
KäyttöohjePDF146 KB
Manuel d'instructionsPDF153 KB
Manuel d'instructionsPDF154 KB
BetriebsanleitungPDF141 KB
BetriebsanleitungPDF140 KB
Οδηγίες χρήσηςPDF160 KB
Οδηγίες χρήσηςPDF158 KB
HandleidingPDF151 KB
HandleidingPDF152 KB
Instruction manual / BetriebsanleitungPDF150 KB
Használati útmutatóPDF152 KB
Használati útmutatóPDF151 KB
Manuale di istruzioniPDF150 KB
Manuale di istruzioniPDF152 KB
Lietošanas pamācībaPDF150 KB
Lietošanas pamācībaPDF148 KB
Instrukciju vadovasPDF152 KB
Instrukciju vadovasPDF150 KB
Instrukcja obsługiPDF152 KB
Instrukcja obsługiPDF153 KB
Manual de instruçõesPDF153 KB
Manual de instruçõesPDF151 KB
Manual de utilizarePDF152 KB
Manual de utilizarePDF151 KB
Návod na poużitiePDF152 KB
Návod na poużitiePDF151 KB
Navodila za uporaboPDF150 KB
Navodila za uporaboPDF149 KB
Manual de instruccionesPDF153 KB
Manual de instruccionesPDF152 KB
ManualPDF147 KB
ManualPDF149 KB
Application reports
Application Report - Controlling and Monitoring liquid Helium at the Deutsches Elektronen-SynchrotronPDF361 KB
Application Report - Digital Communication in Steel-Plate ManufacturingPDF470 KB
Applikationsbericht - Digitale Kommunikation in der Produktion von GrobblechenPDF473 KB
Applikationsbericht - Steuerung und Überwachung der Kälteanlagen im Deutschen Elektronen-SynchrotronPDF643 KB

Relaterte produkter: F.TI0.S12.*08.F.0.***.***.**00

Matching System Components
For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1, IECEx approval, Dust protection, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Division 2 - high-power trunk
Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunkpa

Ethernet-APL enables continuous communication across all hierarchy levels. Learn more about the pioneering technology …

RSS Info Service for PANOS Updates

Stay informed when a new software update of PANOS, the operating system for Ethernet-APL switches, is released: With our RSS Feed you will get an email notfication in your inbox immediately after an update has been released.

From decisions to planning, installation, and commissioning up to operation and maintenance: Discover how to make the most out of your fieldbus infrastructure …