Teknisk support Industrielle sensorer
Kundeservice, eksplosjonsbeskyttelse

Base for read/write station, stainless steel version U-P6V4A-B6

U-P6V4A-B6
  • PROFIBUS DP acc. to EN 50170
  • 2 PG screw fittings for IN and OUT supply
    2 EMV PG screw fittings for BUS IN and OUT
  • Complete read/write functionality via the PROFIBUS DP
  • Transmission of up to 7 double words, 32 bit each, in one cycle
  • Connectable bus termination
  • Field device with degree of protection IP67
  • high-grade steel housing V4A
  • Resistant against cleaning material

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Datablad utdrag: Tekniske data for  U-P6V4A-B6

Produktbeskrivelse
Base for PROFIBUS DP, stainless steel version
Indicators/operating means
DIP switchSetting the station address
bus connection
ON = active  OFF = non-active
Electrical specifications
Rated operating voltage20 ... 30 V DC , ripple 10 %SS , PELV
Power consumptionmax. 5 W with read/write head IPT*-FP
Galvanic isolation
Operating voltage/interfacefunctional insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff
Interface
Physical RS-485
ProtocolPROFIBUS DP acc. to EN 50170
Transfer rate9.6; 19.2; 93.75; 187.5; 500; 1500 kBit/s
3; 6; 12 Mbit/s self-synchronizing
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Degree of protectionIP67 (only in connection with write/read head or cover )
Connectionscrew terminals
Interface cable2 x 0.64 mm2, double screened, acc. to PROFIBUS standard EN 50170
Supplyup to 3 x 1.5 mm2
Material
Housingstainless steel V4A
Dimensions
Height50 mm
Width80 mm
Length161 mm

Classifications

SystemClasscode
ECLASS 13.027280492
ECLASS 12.027280490
ECLASS 11.027280490
ECLASS 10.0.127280490
ECLASS 9.027280490
ECLASS 8.027280490
ECLASS 5.127279212
ETIM 9.0EC002997
ETIM 8.0EC002997
ETIM 7.0EC002997
ETIM 6.0EC002997
ETIM 5.0EC003015
UNSPSC 12.131162301

Details: U-P6V4A-B6

The base is used in combination with an upper part, the IPT*-FP read/write station.

The device is operated as a slave on the PROFIBUS DP. The device makes available the complete read/write functionality. Up to 32 bytes are transmitted per cycle. Of these, up to 7 double words, each with 32 bits, are available to the user.

The address is set and the terminating resistor for the bus is connected via DIP switches.

While the bus termination is switched on, the subsequent subscribers which are connected to the terminals (P, N out) are disconnected from the bus.

Datasheet: U-P6V4A-B6

DatasheetFiltypeFilstørrelse
数据表 U-P6V4A-B6PDF173 KB
Datasheet U-P6V4A-B6PDF701 KB
Datenblatt U-P6V4A-B6PDF702 KB

Documents: U-P6V4A-B6

ManualsFiltypeFilstørrelse
Manual IPTx-FP with U-P6x-B6xPDF2364 KB
Handbuch IPTx-FP mit U-P6x-B6xPDF2471 KB

CAD+CAE: U-P6V4A-B6

CADFiltypeFilstørrelse
CAD 3-D / CAD 3-DSTP458 KB
CAD Portal / CAD PortalLINK---

Approvals+Certificates: U-P6V4A-B6

Declaration of ConformityFiltypeFilstørrelse
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF108 KB

Software: U-P6V4A-B6

Device DriverFiltypeFilstørrelse
GSD file U-P6*-B6* / GSD-Datei U-P6*-B6*ZIP2 KB

Relaterte produkter: U-P6V4A-B6

Matching System Components
LF R/W system, fully assembled as configuration and test stationfa
Visit the RFID Hub

Vi har utviklet en spesiell nettside som skal fungere som en kunnskapsbase for RFID-teknologi. Der finner du svar på vanlige spørsmål, og der kan du få informasjon om vanlige RFID-applikasjoner...