Ikke tilgjengelig: For 8 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Non-hazardous area: screw terminals, black, Number of modules: 8, Number of channels per module: 2 , 4, Signal type: Universal, Manufacturer: Universal, Control system type: Universalpa
Ikke tilgjengelig: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Ikke tilgjengelig: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Ikke tilgjengelig: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Ikke tilgjengelig: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Ikke tilgjengelig: 1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output, Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 19 ... 90 V DC / 48 ... 253 V AC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA (current source), Signal [2]: 1 x 0/2 ... 10 Vpa
Ikke tilgjengelig: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Ikke tilgjengelig: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Få en oversikt over Pepperl+Fuchs' bredeportefølje av HMI-systemer for prosessindustrier ... aluminiumskapsling og er derforpreget av en høygrad av installasjonsfleksibilitet. Med toDisplayPort-interfacestøtter den tilkobling til toUltraHD-skjermer (4K) ved 60Hz. Den har også USBtypeC3.2gen. 1-interface og toUSBtypeA2.0-interface. BTC14 ...
I tillegg til velprøvdefunksjonerleveresTab-Ex®-nettbrett med nyskapendefunksjoner, som integrering av applikasjoner med utvidetvirkelighet, som gjørapplikasjonerinnenIndustri40 / IIoTenkle å implementere ... ProcessorExynos9810 (Lhotse) Octa-Core64-Bit; 4x2.7GHz, 4x1.7GHzQualcommSDM670Octa-Core64bit2,0GHz; 1,7GHzExynos7Octa, 1.6GHzOcta-Core (Cortex®-A53) Display1920x1200pixels (WUXGA), 8" (20,32cm) TFT, 480nits (outdoorspec) 1920x ...
Pepperl+Fuchs’ LoRaWAN-baserteultralydgiverWILSEN er en robustløsning for overvåking av fyllingsnivåsamtavstandsmåling ... releaseofanupdate. IfyouarenotfamiliarwithsettingupanRSSfeed, youcanfindacompactstep-by-stepguideonourwebsiteaswell. Tjenester som hjelper deg med å lykkesUltralydgivere fra Pepperl+Fuchsbygges i vårtegetteknologisenter ...
Pepperl+Fuchsgir deg en komplettIO-Link-systemløsning som omfatter en serieIO-Link-sensorer og infrastruktur ... og identifikasjonsdata. De nyesteIO-Link-produktene For brukere med fokus på å implementerefremtidssikreidentifikasjonsapplikasjoner for Industri4.0tilbyrIQT3* HF-lese/skrive-enheter en ideellløsning. Disse kan raskt og kostnadseffektivtintegreres i arkitekturer ...
LearnmoreaboutthesafeabsolutelinearpositioningsystemsfromPepperl+Fuchs for safetyapplicationsuptoSIL3andPLe ... allowssafeabsolutepositioninguptoSIL3/PLewithjustonesensor . Itcombinesa2-DreadheadwithmulticoloredDataMatrixcodesandisalreadyredundantinitself. Thetwo-colorilluminationofthereadheadmakesonlyonepartofthecode ...
1-5/917Antall produkter pr. side:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.